Skip to content
PPXLROASTERS
PXL Roasters
  • History
  • Plate XIV · section 04 of 13

    The standard, and the zones that do not coincide

    Close-up of a faucet tip, its grille clogged with limescale deposits
    Faucet scaled up by hard water, in southern Arizona: tap water takes its minerals from limestone, and often falls outside the zones recommended for coffeeBbypnda · CC BY-SA 3.0
    ParameterSCA targetAcceptable
    Chlorine, odornone
    Total dissolved solids (TDS)150 mg/L75-250
    Calcium hardness68 mg/L CaCO₃17-85
    Total alkalinity40 mg/L CaCO₃close to 40
    pH7,06,5-7,5
    Sodium10 mg/Lclose to 10
    SCA, Water Quality Handbook; list reproduced by Gagné 2018, p. 2

    On a graph of hardness against alkalinity, the tap waters of big cities line up along a diagonal where the two are equal, because water takes its minerals by dissolving limestone; filter pitchers shift the composition along that same line, toward zero. All the recommendations, SCA, Colonna-Dashwood and Hendon, Zurich, and all the published recipes, are relatively soft waters, hardness under 200 ppm and alkalinity between 20 and 80; most cities in the world have much harder water.

    Paris, for example: 90 mg/L of calcium, 6 of magnesium, 220 of bicarbonates, 10 of sodium, 420 mg/L of total dissolved solids, that is, a hardness of about 250 ppm CaCO₃ and an alkalinity of about 180, outside every zone. The SCA aims at taste; the SCAE drew a narrower zone, alkalinity 40 to 75 and hardness 50 to 175, dictated by scaling and corrosion of machines; the two overlap only in part.

    WaterCaMgHCO₃NaGHKH
    Paris, tap90622010≈ 249≈ 180
    Reverse osmosis≈ 2≈ 0,5≈ 6≈ 1≈ 7≈ 5
    Distilled000000
    Eau de Paris, mineral content table (2026), mg/L; GH and KH calculated; osmosis: order of magnitude, Gagné 2021, p. 30
    ZoneAlkalinityHardnessWhat it aims at
    SCA target4068taste
    SCA acceptable≈ 4017-85taste
    SCAE core40-7550-175the machines
    Published recipes4080-94the filter
    Zurich 201520 preferredsensory trial
    SCA; SCAE; Gagné 2021, pp. 23-27 and 34

    The professional cupping protocol calls for pure, odorless water at between 50 and 150 ppm of total dissolved solids, heated to between 90 and 95 °C, 93 being ideal.

    Gagné 2021, pp. 26-27, composition graph; Eau de Paris, water quality, mineral content table (accessed September 7, 2026); SCAE water chart; professional training document, tasting guide, p. 5
    © 2026 Marco De Sousa Rosa · PXL RoastersTexts under CC BY-NC-SA 4.0 · tools: all rights reserved · images: see the provenanceHome · Colophon · Site map